Hi What is involved in draining and protecting the Auqahot from damage from freezing temps when not in use?How long does it take?Is it a big deal or problematic to do?Thanks all Gyros!
The coolant can be tested for freeze point. As long as test is below the expected low temps, the coolant is good to go.

The fresh water loop can NOT be drained or blown out. It must be winterized with pink fresh water anti-freeze.

Connect a pressure pump to the water hose inlet in the utility bay. Put the suction hose to the pump into a 5 gallon bucket with 2 or 3 gallons of fresh water anti-freeze. Turn pump on and open any one hot water faucet in the coach. When pink comes out of the faucet, the Aqua Hot is winterized.

Hope this helps
Thank you so much!