-
Water bay display board
Forum: Plumbing and fixtures
Last Post: Jack Houpe
4 hours ago
» Replies: 1
» Views: 53 -
SCS 2702 basement air reb...
Forum: Air Conditioning
Last Post: Jack Houpe
4 hours ago
» Replies: 12
» Views: 355 -
HWH RAP1940 6 Pack Air So...
Forum: Air Operated Systems and Leaks
Last Post: encantotom
Yesterday, 04:23 PM
» Replies: 215
» Views: 328,678 -
Lets talk windshields
Forum: Exterior
Last Post: rvguy
Yesterday, 08:23 AM
» Replies: 9
» Views: 247 -
Compressor
Forum: Help, I need help ASAP
Last Post: [email protected]
Yesterday, 07:03 AM
» Replies: 6
» Views: 637 -
SCS A/C and air compresso...
Forum: Parts Swap/Giveaway/Sell
Last Post: Jonestead
08-08-2026, 10:59 AM
» Replies: 2
» Views: 887 -
Buying a 1994 8v92 Newell...
Forum: Please introduce yourself
Last Post: Drea5000
08-08-2026, 08:26 AM
» Replies: 8
» Views: 465 -
Vintage newell coach
Forum: Coaches for Sale (Please read the info in the Category description)
Last Post: Kimmy
08-07-2026, 03:19 AM
» Replies: 3
» Views: 207 -
HWH Touch Panel Problems
Forum: Suggestions
Last Post: Gpgm71
08-06-2026, 08:28 PM
» Replies: 3
» Views: 9,259 -
allison ht741 wont go int...
Forum: Drivetrain
Last Post: [email protected]
08-06-2026, 06:00 PM
» Replies: 5
» Views: 201
- Forum posts:70,388
- Forum threads:8,396
- Members:4,397
- Latest member:Jbice114
I was out on a bicycle ride on the Santa Ana River Trail here in Riverside, CA Friday morning. There is one stretch along the bike path where there are several large storage yards. One of them always has lots of vintage motorhomes. I always look to see if there is anything interesting, and this time I did a double take.......
....and there it was......an early 80's Newell Classic right next to a Blue Bird Wanderlodge. Going to try and go by there and find out about the Newell in the next day, or two. Externally it does not look too bad.
I could only imagine that most of you lay awake at night thinking about replacing your waste tank sensors. Ok, maybe not. Some of mine were giving erroneous signals indicating the tank was partially full when it was not. Since the bride was well tuned in to the sensors in order not to overflow the tank, I received requests (multiple) to correct this situation. I delayed because I had heard horror stories about getting the old ones out.
Getting them out is easy. Seriously, but you have to understand how they seal to make it easy. The screw you see threads into a nut on the other side of the rubber grommet. Tightening the inner nut on the screw tightens against the nut on the other side of the grommet, squishing the grommet, and sealing the hole. If you simply pull on the screw head you compress the grommet even tighter in the hole. Back both the nuts off toward the screw head, push the screw into the grommet about 1/4 inch. Put a small screw driver behind the lip of the grommet and pry the grommet out. If you can get a pair of needle nose pliers between the grommet flange and the tank, it’s even easier.
It took more time to put the zip tie protective covering on the wiring than it did to change all five sensors. And go ahead and remove the fancy water bay covering to gain access. It would be very difficult to do with the cover in place.
Oh yeah, it’s a good idea to empty the waste tank before starting the process.
01-30-2020, 09:33 AM
Forum: Coaches for Sale (Please read the info in the Category description)
- No Replies
Does anyone have any history on this coach? We are looking to move from a front door coach to a mid door coach.
https://www.legacycoach.com/2011-newell-p2000i
Is it ok to steam clean the engine bay and transmission with degreaser ? Do I need to be cautious to any particular device or place?
The title alone will get some attention. To make the story as painless as possible, I will lead with the answers.
We were down to about 4 minute showers when on electric. The real culprit and solution was replacing the Grohe shower cartridge. https://www.amazon.com/gp/product/B002ZL...UTF8&psc=1
On this journey, I also replaced the internals of the tempering valve because that seemed to belikely culprit for cold water. https://www.amazon.com/gp/product/B07XNP...UTF8&psc=1
And while I was at it, installed a double wall flat plate heat exchanger. In hindsight this was overkill but it does provide 20+ minute hot showers on electric, and truly endless hot showers on diesel.
In this graph you can see that with the old cartridge the shower water temp would rapidly plummet. The blue line is the old cartridge, the green line is the new cartridge, and the black line is 100 F representing cold showers. It wasn't quite as severe on diesel, but honestly not a comfortable shower. Now that I have played with it, the signature of a faulty cartridge is a high starting temp, higher than the setpoint, and a rapid decline in output temperature.
I first replaced the Watts tempering valve, and collected data in the shower. In hindsight, the faulty cartridge in the shower obscured whatever improvment the new tempering valve innards made. After thinking about it, the better way to test the tempering valve is at the outdoor faucet, hot water only.
After the Watts repair, and still no joy, I decided to implement the ultimate Aquahot upgrade which the installation of the double wall flat plate exchanger. Here is a poor picture.
If you decide to go down this path, here is how I did it but first let me explain what it does and how it does it. The install will make more sense if you understand the background. In it's stock setup the AH heats potable hot water via a long copper coil wrapped around the outside of the AH tank. The purpose of outside is to provide a double barrier from contaminating potable water with ethylene glycol. Works great for safety, but it is not the best heat exchanger technology. The second thing to understand is that when the AH is running on diesel, the B zone circulation pump runs circulating ethylene glycol in the tank and through the bathroom heating loop. It doesn't get hot in the bathroom because the fans do not come on in the inside radiator. The circulation of the EG in the tank greatly improves the heat transfer to the potable water coil wrapped around the outside of the tank. Easy to see if you imagine hot but stagnant liquid in the tank. As you draw heat away the liquid next to the outer edge of the tank starts to cool. By stirring it you keep hotter liquid in contact with the outer skin of the tank which results in more heat transferred to the hot water loop. That's just dandy if you are running on diesel, but most of us like to use the pedestal power to heat our water, after all that's the purpose of the 220 V megawatt heater, right?
The issue is the EG (ethylene glycol) in the tank does not circulate when using electric, which results in shorter shower times.
A way around the heat transfer inefficiency is to take the circulating EG and pass it through a second add on heat exchanger while passing potable water through the other side of the exchanger. Flat plate exchangers are compact and very efficient, and double wall models provide the potable water protection required. They have been used in Europe to heat potable water for a long time.
This is how I did it. I will break it into three parts: connection and routing of potable water, connection and routing of hot EG, and how to activate the EG circulation when using hot water. Part one, if you look at the incoming cold water pex line to the AH and follow it into the big stainless cover, you see a 6 inch long run of straight copper. Removing the burner helps a lot in this step. I cut a two inch section of that copper line out, and sweated two elbows in. I ran copper from the water in up to the level of the stainless cabinet and terminated with a 3/4 NPT fitting. I used a braided hot water heater hose to connect the incoming(cold) water to the water inlet on the FPHE (flat plate heat exchanger). I used the second elbow and ran copper the same way to the top of the stainless enclosure and also terminated with 3/4 NPT. I connected this line to the water out of the FPHE. This way cold water comes from the incoming, passes through the FPHE, and enters the AH as prewarmed water.
Part two. Clamp the 3/4 inch heater hose north of the middle check valve. Remove the hose from it's barb. Install a short section of new hose with a barb to 3/4NPT fitting on the end. Connect this using a hot water heater hose to the incoming EG side of the FPHE. Connect the outgoing EG to the heater hose you removed with a hot water heater hose and a barb. The water side and the glycol side are now plumbed.
Install a flow valve like this one, https://www.amazon.com/gp/product/B07QNN...UTF8&psc=1 , into the incoming cold water pex line. Provide 12v positive to one wire and run the other wire to the B zone pump relay. It will be easy to spot were to attach since the red (diode) wire from the burner is siamesed here also. This will turn on the circulation pump anytime hot water is used.
Here are the measured results of shower run times take after the modification. The blue line is showering on diesel power, the green line is on electric power, and the yellow line is on electric but without the circulation pump running. It took me about four days, but 3.5 days of that was false starts and faulty approaches. What I posted can be done in half a day.
Many thanks to Bill Johnson for the graphs, data collection, and moral support.
01-29-2020, 03:50 PM
Forum: Coaches for Sale (Please read the info in the Category description)
- Replies (1)
For you bargain hunters who are mechanically inclined and possibly closer to the East coast than I am, this coach looks like an absolute steal for $2,500.
https://rover.ebay.com/rover/0/0/0?mpre=...4051276862
Hey guys I am looking for an answer from those of you that have a steerable tag. I have a real tight spot where I park my current rig (40') and I am wondering if when backing up an 04/05 tag will help me to squeeze in.
Now I have not driven a Newell yet. I did however speak to someone in service at Newell and I was told it does! Everything that I have tried to find online says no.
Can anyone confirm for me? I'm going to buy an 04 or 05 anyway but boy it would be nice if that is true.
TIA
rundlc
Just completed replacing our four #9004 halogen headlight lamps with Super Bright #9004-HLV5 LED lights. They look to be twice as bright
and don't cause the dash mounted voltmeter to indicate in the red when the headlights are on. Our 1991 #277 coach has Ford truck headlights and turn signal housings.
In order to mount the new LED lights, you must trim the plastic headlamp retaining to a maximum width of 0.9125". Remember to trim the back of the retaining ring. The narrower ring allows clearance from the LED cooling fins. I trimmed mine on a circular saw very carefully!
Also, if you need to replace a front turn signal socket, a NAPA # 787131 part is an exact replacement.
Happy camping!
Danny
Howdy all,
About an hour ago at 1200 AZ Time on 25 Jan 2020, I update the forum to most recent version to fix vulnerabilities. If you see any goofy things, problems, or stuff that worked before and isn't now, let me know here so I can take a look at it.
My bedroom air seal had rolled and was coming out of the gap between the slide and the coach. I went through the process of pulling the slide in to expose the seal and got most of it clear and reinstalled. There is a section about 4’ long though that is stuck under the slide between the bottom of the slide and the floor. It seams to be twisted and trapped under there.
Has anybody had this issue. I was thinking about jacking up the slide a bit and maybe free it up. Has anybody ever tryed jacking up the slide and if so were and how did you jack it. I was thinking a 4x4 to spread the load or maybe at the spots we’re the slide runs on the shim plates
I have attached a photo showing how twisted the seal is and I can only believe that what’s trapped underneath is just as twisted.

