Posted by: Fulltiming
12-20-2020, 03:20 PM
Forum: General
- No Replies

Overview of the nearly complete 2022 Florida Show Coach with revised front cap and external 72" projection TV.

https://www.youtube.com/watch?v=93cuMZ6oYNc

Print this item


Posted by: rundlc
12-19-2020, 10:27 PM
Forum: Parts Swap/Giveaway/Sell
- Replies (1)

Looking for some good used aqua hot pumps  model no. 17651-164 only.  If you have any good working ones im looking for spares. 

TIA

Print this item


Posted by: rundlc
12-19-2020, 04:20 PM
Forum: Heating Systems
- Replies (3)

Had a full aqua hot service done today, I thought I had two bad pumps to the "mid" aqua hot/teddy fan and the front drivers whisper fan. Neither of these zones have supplied hot heat since I have owned #746 until today!  It turns out someone prior to me had  cut a wire and the other one was just a bad connection Shame on me for not verifying the connections.

Now that the zones are getting hot water via the aqua hot I only need to solve one issue with the fan at the mid ship register. We cut the wire to the fans and applied 12 volts, HEY Mikie they work!! so fans are not the issue. Next we checked to see if the board on the aqua hot is giving 12 volts, YES it is.

We finally jumped the thermostat/fan on the coach side of the aqua hot board and guess what?? The mid coach fans come on!! YESSSSS  Now the final issue is why doesn't the fan respond to the thermostat???
The Tech thinks that someone didnt set the toggle switches correctly at the ac units on the roof.  Per records found in my owners box all four ac units were replaced around two years ago. Need to get up there and check now.


Any other ideas welcome

Print this item


Posted by: ACR
12-19-2020, 10:56 AM
Forum: Appliances
- Replies (2)

ACR need to remove fridge I took it lose at the bottom but seems it might have other fastening points any help?

Print this item

Listed on Facebook Newell Coach Owners Group, $1,390,000, 25,000 miles, garage kept, 2020P, mid entry.  https://www.facebook.com/gavin.landers/p...4059698455 

Porcelain tile flooring throughout, upgraded outdoor kitchen with grill and refrigerator. Bath and a half.

[Image: 131521610_10224183956375872_233592407319...e=60019243]

[Image: 131301553_10224183937055389_314240275942...e=600403AF]

[Image: 131646764_10224183945415598_323916372532...e=60038F0C]

Print this item


Posted by: folivier
12-17-2020, 07:09 AM
Forum: Parts Swap/Giveaway/Sell
- No Replies

I removed it before I sold my truck.  Bought it about 2 years ago.  It's the BlueOx BX1674 and fits Chevy Silverado 2007-13 and installs in the frame where the tow hooks go.  
New they sell for $450-500.  It should fit in a USPS box so shipping should be no more than $25.00
Make me an offer.

Print this item


Posted by: hbens
12-17-2020, 04:30 AM
Forum: Appliances
- No Replies

I have a water leak behind my stack washer/dryer. I shut off the petcock at the manifold in the utility bay and it doesn't leak.
The leak is slow enough I can do a load of wash and then shut the supply line off.
I read this post's write up and pictures and will be tackling this job in the future http://newellgurus.com/showthread.php?tid=5046

Where does the drain pan drain when water collects in the pan? 

The bay directly below the cabinet is the water bay and the manifold cover blocks my view of where this drain exits the floor. Knowing how Newell designs things I would bet this drains to the outside below the coach or into the grey water piping.

Print this item


Posted by: Fulltiming
12-16-2020, 09:04 PM
Forum: General
- No Replies

Phil Cornelius describes to Andrew Steele the factors that influenced his change from selling Prevost conversions to selling Newells.

https://youtu.be/TTbjVxkTalE

Print this item


Posted by: encantotom
12-16-2020, 07:36 PM
Forum: Electrical
- Replies (1)

hi,  

someone who doesnt post asked me to see if i can find out where the fuse or power is at for the step on a mid 2000's newell with the rugged retracting step.  (not the kwikee).  is there a fuse or terminal block somewhere for the step?

thanks

tom

Print this item


Posted by: Tfrazier
12-16-2020, 04:43 PM
Forum: Electrical
- Replies (10)

Hi all, so just noticed something strange. Up to now we have had no issues watching the tv with the inverter on. We were in the coach last night and none of the TV's would come on. I checked to make sure the inverter was on (switch above micro). It was but I Sent ahead and flipped of and back on. Still no TV. So I Sent and checked the inverter itself and It was powered on. Fast forward to today. I was plugged in to shore power and all of the TV s function properly.So I Sent back over to the  inverter switch and flipped it on. As soon as I did this, the TV's shut off. I don't know much about inverters but this does not seem right. inverter

any ideas,

Merry Christmas

Print this item